Clip and Rail Installation

The rail sections are typically 10’ long and pre-punched 8” on center.

When installing C-RAM SFC-48 or smaller absorber, it is adequate to screw the clip on using every second pre-punched hole. When installing, use low profile heads to avoid interference with the clips.

When installing on modular shielding with wood-core panels, use a self-tapping screw, which penetrates only the first shielding skin and goes into the wood core. Be careful not to penetrate the outer skin (furthest away from the rail). Select the appropriate screw length before use.

When installing on plywood or foil-clad plywood, simply use a wood screw of appropriate length.